Doors and windows Windows and doors tell you a lot in a few seconds: whether the house has moved, whether water is getting in, and whether someone could get out of a bedroom in a fire. The SOP asks you to operate a representative number, so open and close them, lock and unlock them, and look closely at the bedrooms and basement. Operation: a representative number Under § 197-5.12 you observe, operate and report on a representative number of primary windows and interior doors, and under § 197-5.6 the exterior doors and a representative number of windows from outside. "Representative" means enough to give a fair picture, and I always include every bedroom window, because that's where egress matters. What I check: Doors that stick, rub or won't latch. Several doors out of square in one area can point to movement in the framing, so connect it to what you saw in the basement. Windows that won't open, won't stay open, or have broken sash cords, balances or cranks. Painted-shut windows are common in older NYC homes. Broken or cracked glass, missing screens, rotted sills and water stains under windows. Locks that don't work on exterior doors. Write down which ones you didn't operate and why, such as furniture blocking them or windows painted shut. Safety glazing and failed seals Glass in "hazardous locations" must be safety glazing (tempered or laminated) under R308.4 of the 2020 NYS Residential Code. The main ones: glass in doors; glass within 24 inches of a door edge with its bottom less than 60 inches above the floor; large panes over 9 square feet that sit low, near a walking surface; glass in tub and shower enclosures and walls where the bottom is less than 60 inches above the standing surface; and glass next to stairs and landings that's less than 36 inches above the walking surface. There are exceptions in each section. Safety glass usually has a permanent mark etched or fired into a corner (R308.1). If you don't see one in a hazardous location, say "no safety glazing mark was observed" and recommend evaluation. Don't say it's not tempered; you can't tell by looking. Failed seals. Insulated glass (double-pane) has a sealed space between the panes. When the seal fails, you see fogging, haze or droplets between the panes that won't wipe off. It's not a safety issue, but the window loses some insulating value and the glass unit usually needs replacing. Lighting and weather can hide it, so say it may be present in other windows too. Egress and window wells R310.1 requires basements, habitable attics and every sleeping room to have at least one operable emergency escape and rescue opening, and each basement bedroom needs its own. For newer work, R310.2 sets the size: a net clear opening of at least 5.7 square feet (5.0 for grade-floor or below-grade openings), at least 24 inches high and 20 inches wide, and a sill no more than 44 inches above the floor. Window wells must be at least 9 square feet, at least 36 inches each way, with a ladder or steps if deeper than 44 inches. We covered window wells from the outside in Week 3. In older homes, many bedrooms and basement rooms don't meet these numbers, and NY's SOP doesn't ask you to apply today's code. But a room being used as a bedroom with no usable way out is a safety issue. Report it plainly: "The basement room being used as a bedroom has no window or door that appears to serve as an emergency escape opening." Also note security bars without a quick release and windows that won't open. Lead paint on older windows The EPA says homes built before 1978 are more likely to have lead-based paint, and lead dust can form when painted surfaces rub together or are sanded or scraped. Old windows are a prime spot because the sash rubs every time you open it. The SOP says you aren't required to determine environmental hazards (§ 197-5.16(k)), and you can't tell lead paint by looking. What I write for a pre-1978 home: "Due to the age of the home, lead-based paint may be present. Peeling and chipping paint was observed at the window sashes and sills. Recommend lead testing by a certified professional before any work that disturbs paint, and lead-safe work practices." Never sand or scrape paint to check it. Key takeaways: Operate a representative number of windows and doors, including every bedroom window, and note the ones you couldn't. Sticking doors in one area can point to framing movement; connect it to the basement. R308.4: safety glazing in doors, near doors, large low panes, tub and shower areas, and near stairs. Say 'no safety glazing mark observed' rather than 'not tempered.' Fogging between panes means a failed insulated glass seal. R310: every bedroom and basement needs an escape opening; pre-1978 homes may have lead paint, especially at windows.